At
FOUJI we take utmost care in all aspect while manufacturing compressors
however for longevity and proper functioning of compressors, instructions
given must be followed.
IMPORTANT POINTS TO BE OBSERVED PERIODICALLY ON AIR COMPRESSORS.
- Tension of the
V-belt to be checked up every week.
- Starter's Amp.
calibration should agree to the Electric motor.
- Connect the
Electric motor to the required mains properly and observe safety
measures.
- Electric motor
(rotation) must run anticlockwise as per arrow direction.
- Adjust the Automatic
pressure switch and safety valve equally and to the required pressure.
- Check up the
firmness of the fasteners (bolts and nuts) periodically to avoid
loosening and vibration.
- Do not run the
compressor without oil up to the required level.
SOME USEFUL SUGGESTIONS
(A)
Use lubricating oil D. T. E. Oil heavy medium or D. T. E. Oil extra
heavy duty of standard Vacuum Co. Oil as good as those mentioned
above or oils which set free few carbon are suitable. But we have
to change thickness of oil we use according to room temperature
or season. For instance in summer, it is better to use thicker oil.
When it is hard to get ideal lubrication oil, we often use automobile
oil as substitute, namely, in summer No. 30 auto-oil and in winter
No. 40. The quantity of oil in crank-case is proper when oil level
goes up to the half point of the gauge. When oil becomes dirty,
strain it or change it with new one.
(B)
Adjust stretch of belt. When two belts are used, stretch of both
must be same. When stretch of two belts are not same, overload on
electric motor will occur.
(C)
Direction of revolution must follow arrow direction on cylinder
pulley. When it turns in the opposite direction, feathers of pulley
will not work for cooling air.
(D)
Disassemble suction filter frequently, and take care that no dust
enters the cylinder.
(E)
Disassembling & Cleaning must be done carefully; especially
dust must be removed completely. Careless or rough "disassembling
& cleaning" makes machine worse.
(F)
If your hear queer noise on machine, stop running the machine at
once examine obstacles and repair it.
(G)
Look at pressure gauge, as less pressure goes up over a certain
kgs.
(H)
Once in two or three days loosen drain cock which is on the lower
part of tank and run machine to drain, give a little pressure in
tank. Keep carefully the certificate for proof-pressure of tank.
(I)
Examine if pressure gauge has any trouble or not. Sometimes you
believe that pressure doesn’t go up because of some trouble
on machine while not knowing breakdown of gauge.
(J)
Keep machine level proper when in use.
(K)
Fixed machine gives less vibration when in drive.
(L)
When belt becomes too long, pull motor back and make belt tight.
(M)
Pay attention if voltage drops. Sometimes motor causes trouble when
you run machine inspite of voltage - drop.
GUARANTEE
We assure to replace, free of charge, within one year from date
of sale, any "Fouji" air compressor which in its judgment has failed
because of defective material or workmanship, provided it has been
shown to have been properly mounted. Properly maintained and not
subjected to abuse in operation or handling. Such compressor must
be returned to the factory charges prepaid and with complete information
as to service. We assume no responsibility for contingent or consequential
damage in any event.
This guarantee is in lieu of all warranties either expressed
or implied.
FINDING CAUSES OF INCIDENT AND REPAIRING
(a)
Queer noise is heard in case.
- Key of pulley
loosen.
- Bolts and nuts
on piston-rods loosen.
- Rod wears away.
- Crank-shaft
bearing wears away.
- Suction valve
or exhaust valve breaks.
(b)
Pressure doesn’t go up in case.
- Head gasket
worn seat.
- Piping in air
tank or other circulation pipe has air-leaking.
- Valve on cylinder-head
worn away extremely and plate is not close together with seat.
- Safety valve
leaking (owing to trouble of safety valve)
- Suction or exhaust
valve is broken.
(c)
Sudden stop of running machine in case.
- Lubrication
oil doesn’t circulate completely.
- Trouble of worn
parts.
- Extreme voltage
drop.
EXPLANATION ON AUTOMATIC SWITCH
(a) Action of automatic switch
Compressed air in compressor enters air tank through subsidiary
copper tube (1) and catch valve. When air pressure in air tank goes
up to a certain kgs. Compressed air in air tank goes through copper
tube and pushes spring in automatic switch. The switch works on
lever, which cuts off electric current. Rotation of motor stops,
after the compressor stops to move. At the same time by work of
lever of automatic switch release - valve is opened and air in subsidiary
tank and in copper tube (1) is discharge (if relief valve is there).
When air pressure in air tank goes down, pressure on switch
falls, and the lever in automatic switch comes back to former state
by action of spring. The electric current which was cut off is connected
again and the motor starts to move and at the same time release
valve will be closed.
(b) Object
It is not desirable to run air-cooling type compressor for long
time with high pressure. When enough pressure is obtained it is
necessary to stop compressor. This switch is used when compressor
is not used continually to make it move all time.
(c) Starting
When compressor stops to work by action of automaic switch,
release - valve opens at the same time. There is no compressed air
in subsidiary tank. In this case, when motor begins to work, it
does normal movement, but when you want to run comressor again after
you cut off main switch you have to open drain cock and discharge
compressor air in subsidiary tank.
Unless you don't discharge air of tank, over-land on motor
will occur. Sometimes motor will burn up. There is no trouble when
no pressure is in tank.
(c) Regulation of Pressure
To change limit of desired pressure, look at the back side of
cover of automatic switch, you will find details of direction on
it. Turn screw to the left or right as you like to regulate.
(d) Obstacles
While operating compressor, if rise of pressure is slow, air
is leaking through air-cock under subsidiary tank or valve attached
on automatic switch. While comressor is stopping, pressure goes
down suddenly there must be dust in non return valve. For air in
tank goes out from this valve through subsidiary air tank and copper
tube.
(e) Atttention
Compressor with automatic switch stops movement when pressure
goes up to a certain degree. So it is unnecessary to cut off main
switch while you take a rest. Cutting off main switch sometimes
becomes cause of trouble of motor We hope you pay attention about
the fact. After long time, stopping of machine or after you finish
work if you cut off main switch, you have to discharge pressure
in subsidiary tank. In case, you want to start to run the machine
again as mentioned above and it is desirable to open cock under
subsidiary tank and drain occasionally.
Top
|